GENERAL DESCRIPTION
below 95%, or (b) that the total mass
loading of the filter is less than 200mg
for a single canister application or less
than 100 mg each for a dual cartridge
application).
2. GMHF-C-P100 and Hydrogen
Fluoride/P100: Canister must be
replaced after each use against hydro-
gen fluoride (not to exceed 12 hours) to
ensure the integrity of the P100 filter.
F MULTI-USE LIMITATIONS (OptiFilter XL
only)
1. Approved as a high efficiency particulate
air filter on approved Powered Air
Purifying Respirators. Also, approved as
a P100 filter, but ONLY when used with
an approved negative pressure respira-
tor. Do not exceed maximum use con-
centrations established by regulatory
standards.
EXPOSURE LIMITS
A listing of applicable exposure limits from
the following sources is provided in MSA s
Response
®
Respirator Selector: available
online at www.MSAnet.com.
- American Conference of Governmental
Industrial Hygienists (ACGIH)
- Occupational Safety and Health
Administration (OSHA)
- National Institute for Occupational
Safety and Health (NIOSH)
- American Industrial Hygiene Association
(AIHA)
Contact MSA at 1-800-MSA-2222 for infor-
mation.
EXPOSURE LIMITS FOR MIXTURES
The American Conference of Governmental
Industrial Hygienists (ACGIH) publishes the
following information to determine the TLV
of a mixture.
First, determine the total concentration of
the chemical mixture (C ) from the individual
contaminant concentrations (C
1
, C
2
, C
3
...)
using the following formula:
C
Mixture
= C
1
+C
2
+C
3
+...
The TLV of the mixture is found by using the
following formula where T
1
, T
2
, T
3
, ... are
the individual contaminant TLVs and C
1
,
C
2
, C
3
... are the individual contaminant
concentrations:
Only use these equations if the contami-
nants present are actually mixed. Some
substances do not mix and may be present
separately, for example, in pockets or at dif-
ferent levels. In that case, the lowest TLV of
the substances present must be used to
determine the appropriate respirator cate-
gory for protection against all contaminants
present.
See MSAs Response Respirator Selector
for additional information.
TAL 115 (L) Rev. 23 - 430351
11
C
mixture
T
mixture
C
1
T
1
+
C
2
T
2
+
C
3
T
3